We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

AIMS: Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial. METHODS AND RESULTS: Fifty-six consecutive patients underwent OCT during angiographic follow-up at 9 months. OCT images were acquired using a non-occlusive technique at a pullback speed of 3 mm/s. Data were analysed using a Bayesian hierarchical random-effects model, which accounted for the correlation of lesion characteristics within patients and implicitly assigned analytical weights to each lesion depending on the number of struts observed per lesion. Primary outcome was the difference in percentage of uncovered struts between BESs and SESs. Twenty patients were included in the analysis in the BES group (29 lesions with 4592 struts) and 26 patients in the SES group (35 lesions with 6476 struts). A total of 83 struts were uncovered in the BES group and 407 out of 6476 struts were uncovered in the SES group [weighted difference -1.4%, 95% confidence interval (CI) -3.7 to 0.0, P = 0.04]. Results were similar after adjustment for pre-procedure lesion length, reference vessel diameter, number of implanted study stents, and presence of stent overlap. There were three lesions in the BES group and 15 lesions in the SES group that had > or =5% of all struts uncovered (difference -33.1%, 95% CI -61.7 to -10.3, P < 0.01). CONCLUSION: Strut coverage at an average follow-up of 9 months appears to be more complete in patients allocated to BESs when compared with SESs. The impact of this difference on clinical outcome and, in particular, on the risk of late stent thrombosis is yet to be determined.

Original publication

DOI

10.1093/eurheartj/ehp480

Type

Journal article

Journal

Eur Heart J

Publication Date

01/2010

Volume

31

Pages

165 - 176

Keywords

Absorbable Implants, Coronary Restenosis, Drug-Eluting Stents, Female, Graft Occlusion, Vascular, Humans, Male, Middle Aged, Polymers, Sirolimus, Tomography, Optical Coherence, Treatment Outcome, Tubulin Modulators