We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown. METHODS: The LEADERS trial compared the performance of BES with that of SES. Patients were randomly allocated to a sequential angiographic follow-up, including OCT in selected sites, at 9 and 24 months. Struts coverage was compared using Bayesian hierarchical models as the primary outcome for the OCT substudy. RESULTS: Fifty-six patients (26 BES, 30 SES) were enrolled in the OCT substudy. Twenty-one patients (10 BES, 11 SES) agreed to perform a second OCT follow-up at 24 months. Eleven lesions and 12 stents were analyzed sequentially in the BES group (2,455 struts at 9 months, 2,131 struts at 24 months) and 11 lesions and 18 stents in the SES group (3,421 struts at 9 months, 4,170 struts at 24 months). The previously reported advantage of BES over SES in terms of better strut coverage at 9 months was followed by improvement in coverage of the SES, resulting in identical coverage in both BES and SES at 24 months: 1.5% versus 1.8% uncovered struts, difference -0.2%, 95% credibility interval, -3.2% to 2.6%, P = .84. CONCLUSIONS: More complete strut coverage of BES as compared with SES at 9 months was followed by improvement of coverage in SES between 9 and 24 months and a similar long-term coverage in both stent types at 24 months.

Original publication

DOI

10.1016/j.ahj.2011.09.005

Type

Journal article

Journal

Am Heart J

Publication Date

11/2011

Volume

162

Pages

922 - 931

Keywords

Adult, Angioplasty, Balloon, Coronary, Case-Control Studies, Coronary Stenosis, Drug-Eluting Stents, Female, Humans, Immunosuppressive Agents, Male, Polymers, Randomized Controlled Trials as Topic, Serum Albumin, Serum Albumin, Human, Sirolimus, Tomography, Optical Coherence, Treatment Outcome