We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Volume-clamp technology (e.g. Finometer) has become a popular method of collecting continuous, non-invasive, hemodynamic information during hemodialysis. There is minimal data validating the technique in this patient group. A gold standard cardiac output measurement can be obtained using ultrasound dilution in patients with arterio-venous fistulae. Continuous cardiac output was measured in 124 hemodialysis sessions in 27 patients using a volume-clamp device (Finometer PRO). Ultrasound dilution measurement was first taken at baseline (Transonic HD03), then used to calibrate the Finometer. Ultrasound dilution measurement was repeated 2 h into hemodialysis to assess drift following calibration. Pearson's correlation and Bland-Altman statistics, modified for repeated measures, were used to assess agreement between methods. Linear mixed models were constructed to identify factors that could explain session-level and patient-level variation in agreement. For baseline cardiac output before calibration, agreement between volume-clamp and ultrasound dilution measurements was poor, at 25 ± 75% (correlation 0.26, P < 0.001). There was significant variation in agreement between patients, with age, peripheral vascular disease and hemodialysis vintage contributing to poorer agreement. For cardiac output 2 h after calibration, agreement was -5.2 ± 57.5% (correlation 0.6, P < 0.001). Dynamic changes in blood pressure and fluid balance during hemodialysis resulted in greater drift over time after calibration. There was a large error, both random and systematic, in volume-clamp estimates of absolute, pre-calibration cardiac output in this prevalent hemodialysis population. There was minimal bias and reasonable correlation for cardiac output 2 h post-calibration, but limits of agreement remained too wide to meet current clinical standards.

Original publication

DOI

10.1111/1744-9987.12650

Type

Journal article

Journal

Ther Apher Dial

Publication Date

10/01/2018

Keywords

Cardiac output , Hemodialysis patients , Measurement error